AEG CaFamosa Coffee Grinder: Replacing and Adjusting Grinding Burrs (Grinding Ring and Cone)

AEG CaFamosa Coffee Grinder: Replacing and Adjusting Grinding Burrs (Grinding Ring and Cone)

Overview and applicability

This technical article covers the disassembly, replacement, and reassembly of the conical burr set—consisting of the grinding cone (Mahlkegel) and grinding ring (Mahlring)—in the coffee grinder assembly of the AEG CaFamosa espresso machine line.

The procedure addresses worn burrs that lead to poor grind quality or inconsistent coffee extraction. Applicability is confirmed specifically for AEG CaFamosa grinder assemblies. Other machine families or specific sub-variant model numbers are not confirmed.


Symptoms and diagnosis

Worn grinding burrs typically result in coffee grounds that are too coarse, uneven grind consistency, or extended grinding cycles without producing adequate coffee volume.

The procedure directly targets mechanical replacement of the cutting surfaces (the inner grinding cone and outer grinding ring) within the standalone grinder motor housing.


Tools, materials, and replacement parts

Required tools

  • Torx T20 screwdriver

  • Slotted (flathead) screwdriver, Size 5 (approx. 5 mm blade width)

Replacement parts and hardware

  • Replacement grinding ring (Mahlring)

  • Replacement grinding cone (Mahlkegel)

Note: Part numbers, exact burr metallurgy, and specific torque specifications are not stated.


Products for this guide

Preparation and precautions

  • Electrical safety: Disconnect the machine from electrical mains power by unplugging the power cord before any maintenance.

  • Liquid and debris removal: Empty or remove the water tank. Empty the bean hopper as thoroughly as possible (a vacuum cleaner can be used to remove residual beans and grounds).

  • Sub-assembly state: This procedure begins with the grinder assembly already removed from the machine chassis. Accessing and removing the grinder from inside the coffee maker housing is outside the scope of this procedure.


Step-by-step procedure

1. Removing the adjustment collar and marking alignment

  1. Locate the black outer adjustment ring (toothed ring) at the top of the grinder assembly.

  2. Unclip the three retaining tabs (Haltenasen) securing the outer ring to the upper grinder housing.

  3. Lift the black outer ring straight off the housing and set it aside.

  4. Inspect the factory alignment markings on the white plastic components. Ensure that the alignment mark visibly spans all three relevant parts (the outer adjustment ring, the inner housing, and the ring holder). If the line is not visible across all parts, remark the alignment using a pen or marker before proceeding.

2. Disassembling the upper grinder and removing the outer burr holder

  1. Rotate the outer threaded ring counterclockwise until it unscrews and releases.

  2. Pull the upper grinding ring holder (Mahlringhalter) straight up and out of the grinder assembly.

  3. Set the housing and motor assembly upright on the work surface.

3. Removing the central drive screw and grinding cone

  1. Locate the central fastener holding the intake auger (Einzugsschnecke) and grinding cone in the center of the grinder cavity.

  2. Insert a flathead screwdriver into the central screw head.

  3. Hold the inner grinding cone firmly with one hand to prevent it from spinning while turning the central screw counterclockwise to loosen it.

  4. Continue holding the grinding cone firmly while lifting out the loose central screw and the intake auger.

  5. Grasp the center of the grinding cone, rotate the grinder unit, and slide the grinding cone and underlying carrier disk (Förderteller) downward and out of the housing.

4. Disassembling the carrier disk, springs, and ball bearings

  1. Separate the carrier disk assembly from the grinding cone.

  2. Carefully pull the three tension springs out of their respective recessed holes in the plastic carrier disk.

  3. Remove the carrier disk to access the three internal steel ball bearings beneath it.

  4. Remove the three ball bearings and set them aside safely to prevent them from rolling away.

5. Removing and replacing the outer grinding ring

  1. Take the grinding ring holder (Mahlringhalter) that was removed in Step 2.

  2. Use a flathead screwdriver to carefully press the two internal retaining tabs inward and slightly downward to release the lower housing section.

  3. Separate the lower section and the sealing ring/gasket from the upper holder.

  4. Use a flathead screwdriver to gently push one of the retaining tabs outward to free the worn grinding ring.

  5. Tip the holder to drop the worn grinding ring out of the plastic collar.

  6. Take the new replacement grinding ring and align it under one of the retaining tabs.

  7. Press the new grinding ring firmly into the holder until it snaps securely into place under both tabs.

  8. Reinstall the seal and lower housing section onto the grinding ring holder:

    • Ensure the alignment tabs on the lower part match the openings in the holder.

    • Slide the lower part back into the holder until the retaining tabs click and lock into place.


Reassembly and testing

1. Reassembling the carrier disk and ball bearings

  1. Place the new grinding cone onto the plastic carrier disk (Förderteller), ensuring the holes line up precisely.

  2. Insert the three steel ball bearings into their individual holes in the carrier disk.

  3. Place the three tension springs into the holes directly above the steel balls.

  4. Insert the assembled carrier disk into the grinder body:

    • Align the three protruding springs with the corresponding recesses in the internal base of the grinder housing.

    • Seat the assembly firmly into position.

2. Installing the intake auger and center screw

  1. Check the coffee exit chute to confirm the carrier assembly is fully seated.

  2. Place the plastic intake auger onto the central shaft:

    • Ensure the guide tab (Führung) of the auger fits cleanly into the corresponding notch (Nut) of the carrier disk.

  3. Insert the central mounting screw into the center of the auger.

  4. Hold the intake auger down securely with a thumb to keep it locked into the notch while tightening the center screw with the screwdriver.

  5. Critical visual check: Inspect the grinder through the lateral coffee ejection chute. There must be no visible gap between the grinding cone and the lower carrier disk. If a gap exists, disassemble the central mount and verify the spring and ball alignment.

3. Reinstalling the outer grinding ring and basic calibration

  1. Seat the reassembled grinding ring holder into the top of the grinder housing.

  2. Thread the outer ring clockwise into the housing.

  3. Turn the ring clockwise until the alignment marks made during disassembly form a straight, continuous line across the components.

  4. Take the black toothed adjustment collar and align it over the top assembly.

  5. Press the collar downward until its three retaining tabs snap firmly into place around the perimeter.


Result and troubleshooting if the issue persists

Following this procedure, the grinder's cutting geometry is restored to factory spacing based on the original alignment marks.

Troubleshooting

  • Grinder jams or motor stalls: Disassemble the central screw and verify that the three steel balls and springs were seated correctly in their recesses, and that no gap exists between the grinding cone and the carrier disk.

  • Grind remains too coarse or inconsistent: The black adjustment ring can be shifted by stepping the outer ring relative to the housing teeth to calibrate finer or coarser settings.

  • Grinder fails to run electrically: Check all wiring and terminal connections that were disconnected when removing the grinder from the machine chassis.


Limitations and missing specifications

  • Chassis disassembly: The process for opening the AEG CaFamosa housing and physically extracting the grinder module prior to burr service is not detailed.

  • Torque values: No explicit torque specifications are available for the central drive screw; components are tightened manually until snug while holding internal components stationary.

  • Part dimensions: Exact dimensions, tooth counts, and manufacturer part numbers for the replacement cone and ring are not specified.

Related guides

Browse AEG CaFamosa repair guides