AEG Caffe Grande CG and Caffe Silenzio CS: Thermoblock Removal

AEG Caffe Grande CG and Caffe Silenzio CS: Thermoblock Removal

Overview and applicability

This technical guide covers the removal of the thermoblock (heating element assembly) from the chassis of an automatic coffee machine.

This procedure applies directly to:

  • AEG Caffe Grande CG

  • AEG Caffe Silenzio CS

The demonstrated mechanical layout and steps are shown using a structurally identical DeLonghi EAM / ESAM series chassis. Casing panel removal is not covered in this procedure; the machine must already have its exterior side and top panels removed before beginning.

Symptoms and diagnosis

Removal of the thermoblock is typically indicated when the heating unit suffers from electrical failure (such as an open heating circuit or blown thermal fuses), internal calcification, or persistent fluid leakage from the casing or fittings.

In this procedure, diagnosis and electrical measurements are not demonstrated. The component is removed directly from an open chassis for replacement or bench overhaul.

Tools, materials, and replacement parts

Required tools

  • Needle-nose pliers

  • Phillips screwdriver (PH2)

  • Open-end wrench (spanner), size 7 mm

Parts and materials

  • No specific replacement part numbers or chemical sealants are established in the demonstrated procedure. If replacing the thermoblock or reattaching pressure lines, matching replacement seals (O-rings) and clips for the fluid couplings must be verified according to manufacturer parts catalogues.

Preparation and precautions

  • Electrical safety: Disconnect the machine completely from the mains power supply by pulling the power plug. Never perform disassembly or touch internal wiring on an energized appliance.

  • Burn hazard: Ensure the thermoblock has fully cooled to ambient room temperature before handling.

  • Water spillage: Remove and empty the water tank. Residual water remains inside the thermoblock and connecting hoses; have absorbent cloths available to catch dripping water when pressure hoses are detached.

  • Hopper clearance: Empty coffee beans from the bean container as thoroughly as possible (for example, using a vacuum cleaner) to prevent loose beans from falling into open chassis components.


Step-by-step procedure

1. Disconnect thermoblock wiring from the power board

  1. Locate the main power electronics board mounted vertically on the side of the chassis.

  2. Identify the wiring harness leads routed from the thermoblock to the power board.

  3. Using needle-nose pliers or fingers, carefully pull the thermoblock spade connectors straight off their matching terminals on the circuit board.

2. Unthread wiring from chassis guides

  1. Trace the disconnected thermoblock cables as they travel along the machine chassis toward the top.

  2. Unthread and free the cables from the molded plastic cable routing clips and chassis channels.

  3. Pull the wiring harness upwards so that it rests loosely near the top thermoblock assembly.

3. Disconnect the microswitch terminals

  1. Look at the top of the thermoblock assembly to locate the mounted microswitch.

  2. Using needle-nose pliers or fingers, grasp the two electrical push-on connectors attached to the microswitch tabs.

  3. Pull both connectors straight off the microswitch.

4. Remove the protective earth (ground) connection

  1. Locate the green-and-yellow protective earth ground wire secured to the metal thermoblock frame.

  2. Using the PH2 Phillips screwdriver, loosen and remove the fastening screw securing the ground eyelet terminal.

  3. Set the grounding screw aside and lift the ring terminal off the mounting post.

5. Disconnect the upper pressure hose

  1. Locate the upper rigid Teflon pressure hose coupling on the side of the thermoblock assembly.

  2. Using needle-nose pliers, grip the metal hairpin retaining clip (U-clip) securing the hose fitting.

  3. Pull the clip straight out from the connector body.

  4. Grip the pressure hose near the fitting and pull it straight out of the coupling. Be prepared to catch any residual water droplets.

6. Disconnect the lower pressure hose

  1. Reposition to access the lower pressure hose connection located further down on the side of the assembly.

  2. Using needle-nose pliers, pull the retaining U-clip horizontally out from the lower coupling.

  3. Pull the lower pressure hose firmly out of its port.

7. Remove the four thermoblock mounting fasteners

  1. Locate the four vertical Phillips screws securing the thermoblock bracket to the chassis.

  2. Note that each mounting screw is secured from underneath the chassis bracket by a size 7 mm counter-nut.

  3. Position the 7 mm open-end wrench underneath the bracket to hold the counter-nut stationary.

  4. Using the PH2 Phillips screwdriver from above, unscrew the fastener while counter-holding the nut from below.

  5. Repeat this process for all four mounting screws, ensuring that all four screws and their counter-nuts are collected and not dropped into the chassis.

8. Detach the silicone hose and lift out the thermoblock

  1. Locate the flexible silicone drainage/overflow hose connected to the rear upper port of the assembly.

  2. Pull the silicone hose off its plastic hose barb.

  3. Ensure all previously disconnected cables, hoses, and wiring are clear of the mounting bracket.

  4. Grasp the thermoblock firmly and lift the entire assembly upward and out of the machine housing.


Reassembly and testing

The removal sequence concludes once the thermoblock is lifted clear of the chassis. Reassembly involves reversing the removal steps:

  1. Lower the replacement or serviced thermoblock into the chassis mounting position.

  2. Reattach the silicone hose to its rear barb.

  3. Align the four mounting holes and install the four screws from above, securing them with the 7 mm counter-nuts from underneath.

  4. Inspect the pressure hose ends and install fresh pressure seals (O-rings) if required. Insert both the upper and lower pressure hoses fully into their respective ports until seated, then lock each with its metal retaining clip.

  5. Fasten the protective earth ground wire securely to the metal thermoblock frame using its retaining screw.

  6. Reconnect the two spade connectors to the microswitch.

  7. Route the power and sensor cables down through the plastic chassis clips to the vertical power board, and push the connectors firmly onto their corresponding terminals.

  8. Reinstall the housing panels before reconnecting mains power.

  9. Perform a test cycle while inspecting all fluid couplings for leaks and verifying correct heating operation.

Result and troubleshooting if the issue persists

Completing this procedure frees the thermoblock assembly from the machine chassis, allowing for bench inspection, component descaling, replacement of heating loops or thermal cutoffs, or complete unit exchange.

If the machine fails to heat or leaks after replacing or reinstalling the thermoblock:

  • Water leakage at hose couplings: Verify that the pressure hose was inserted deep enough into the port before the retaining clip was slid into place, and inspect the coupling O-rings for cuts, pinching, or wear.

  • No heat or error display: Check that all power board spade connectors and microswitch leads are fully seated on their correct terminals. Verify continuity across the heating coils and thermal fuses using a multimeter if heating remains non-functional.

  • Loose assembly: Ensure all four 7 mm counter-nuts were counter-held and tightened properly against the chassis bracket.

Limitations and missing specifications

  • Fastener torques: Tightening torques for the four mounting screws and the protective earth screw are not specified.

  • Seal specifications: Dimensions and material specifications for the internal coupling O-rings are not detailed in the demonstrated removal.

  • Electrical schematics: Specific pinout assignments and terminal designations on the power board are not labeled; connectors should be tagged or photographed before removal to ensure accurate reinstallation.

  • Housing disassembly: Preceding steps required to remove the external machine casing are omitted.

Related guides