Overview and applicability

This technical reference identifies the primary internal components and their physical locations within the Jura A-series automatic coffee machine line. The layout is based on the structurally equivalent Jura ENA Micro platform, which shares the same internal chassis configuration and functional subsystem architecture.

This documentation serves as a spatial and component-identification guide for maintenance and service work. It does not provide disassembly fastener sequences, torque specifications, or part numbers.


Products for this guide

Safety precautions and preparation

Before opening the housing or touching internal assemblies:

  • Disconnect electrical power: Unplug the machine completely from the mains wall socket.

  • Empty the water system: Remove and empty the external water tank.

  • Clear the bean hopper: Remove all coffee beans from the bean container as thoroughly as possible (for example, using a vacuum cleaner) to prevent beans and debris from spilling into the open chassis.

  • Electrostatic and electrical safety: Work involving electrical and electronic modules must comply with electrostatic discharge (ESD) protections and local electrical standards (such as DIN VDE regulations).


Internal component locations

With the outer housing panels removed, the internal subsystems are distributed across four main visual orientations.

Right-side layout

Viewing the machine from its right side (with the front spout to the right):

  • Kaffeeauslauf (Coffee spout): Positioned at the exterior front, routing brewed coffee from the brewing group to the dispensing outlet.

  • Brüheinheit (Brewing unit): Positioned centrally inside the right chassis compartment. The brewing group mechanism handles tamping, extraction, and puck ejection. For Jura A1, A5, A7 and A9, the complete Jura brewing unit 70173 is the complete-assembly replacement option for this component.

  • Flowmeter: Located near the bottom rear corner, measuring fluid intake volume from the water reservoir before it reaches the pump.

  • Trichter (Chute / Funnel): Positioned in the upper region above the brewing unit, directing ground coffee from the grinder into the brew chamber.

Rear layout

Viewing the machine directly from the back:

  • Ventildrücker (Water tank valve actuator / pin): Located in the upper section of the rear chassis, engaging the spring-loaded discharge valve of the seated water reservoir.

  • Netzfilter (Mains line filter): Positioned in the lower chassis compartment adjacent to the power cord inlet, suppressing electrical interference on the incoming alternating current supply.

Left-side layout

Viewing the machine from its left side (with the front spout to the left):

  • Pumpe (Water pump): Mounted vertically toward the rear of the left compartment to generate system water pressure.

  • Membranregler (Membrane regulator): Mounted directly to the pump outlet to dampen pressure oscillations and reduce hydraulic vibration noise.

  • Elektronik (Power electronics board): Mounted flat against the middle section of the left chassis frame, controlling line-voltage switching and subsystem distribution.

  • Keramikventil (Ceramic valve): Mounted toward the lower front quadrant, distributing pressurized hot water and steam to the brewing and dispensing circuits.

  • Thermoblock: Mounted in the upper front quadrant of the left compartment, heating cold incoming water to brewing or steam temperatures.

Top layout

Viewing the chassis from above (with the front user interface facing forward):

  • Mahlwerk (Grinder): Occupies the central-to-rear section of the upper deck, grinding whole coffee beans directly into the chute.

  • Mikroschalter (Microswitch): Positioned adjacent to the ground coffee channel/grinder assembly to detect lid closure or mechanical positioning.

  • Steuerelektronik (Control electronics): Mounted at the front of the top assembly behind the user control interface, processing input commands and driving the display or indicator lights.


Limitations and missing specifications

  • Fastener details: Screw types, lengths, head drives (such as oval head or Torx), and latch clip release points required to remove the outer panels are not specified.

  • Fluidic and electrical ratings: Operating pressures, thermoblock wattage, pump voltage, flowmeter pinouts, and fuse ratings are not documented in this layout overview.

  • Model variations: While the internal architecture is shared across the Jura A-series and Jura ENA Micro lines, individual model variants may feature differing spout designs (e.g., standard coffee versus one-touch milk frothing components).

Related guides