Jura E6 Error 2 Diagnosis, Temperature Sensor Replacement, and Brewing Unit Overhaul

Jura E6 Error 2 Diagnosis, Temperature Sensor Replacement, and Brewing Unit Overhaul

Overview and applicability

This technical article details the diagnosis and repair of an "Error 2" fault on a Jura E6 automatic coffee machine, along with the overhaul and re-sealing of its brewing unit.

The procedure covers:

  • Identifying the source of the "Error 2" fault code.

  • Opening the outer housing.

  • Removing, testing, and replacing the heating element temperature sensor (NTC sensor).

  • Disassembling, deep-cleaning, and rebuilding a heavily contaminated brewing unit (marked with a 2015 production stamp in this case) including the drainage valve.

  • Performing functional verification.

The speaker mentions in passing that the housing and brewing unit removal is similar to the Jura E8, but detailed applicability beyond the Jura E6 is not verified in this procedure. Do not apply these steps to other models without confirming fastener locations and component wiring.

For temperature-sensor and brew-group identification, consult the Jura E6 exploded-view diagram.

Symptoms and diagnosis

  • Demonstrated symptom: Upon switching the machine on, the display briefly shows "Willkommen bei JURA" followed immediately by a red fault screen stating "ERROR 2 / Bitte kontaktieren Sie den JURA-Kundendienst" (Please contact JURA customer service). The machine aborts initialization and does not heat.

  • Cause: Error 2 indicates a failure in the heating element temperature sensing circuit (the NTC thermistor sensor located on the thermoblock).

  • Secondary finding: Upon removing the side panels, severe internal contamination from old coffee grounds, mold, and dried coffee residue was discovered inside the brewing chamber, around the drainage valve, and throughout the brewing unit assembly.

  • Diagnostic check:

    • Measuring electrical resistance across the two leads of the removed original temperature sensor with a digital multimeter showed an open circuit (0.L / out of limits), confirming that the internal thermistor or wiring was broken.

    • A new replacement sensor measured approximately 132\text{ k}\Omega\text{ to }137\text{ k}\Omega at ambient room temperature, confirming circuit continuity and standard NTC behavior.

Tools, materials, and replacement parts

Tools used

  • Electric screwdriver / drill driver with extension bit holder

  • Jura oval-head bit (specialty security tool for Jura rear panel fasteners)

  • 4 mm Allen / hex key or bit (for the thermoblock bracket fastener)

  • Torx screwdrivers / bits (used for general housing and brewing unit screws)

  • Flathead screwdrivers (fine and medium, used for releasing clips and removing stubborn buildup)

  • Needle-nose pliers

  • Cleaning brushes (bristle paint brush)

  • Workshop vacuum cleaner

  • Digital multimeter with probe leads

Replacement parts and consumables

  • Jura E6 NTC temperature sensor: Cable assembly terminating in an eyelet lug at the sensor end and a small 2-pin white plastic female connector at the control board end. Exact manufacturer part number is not stated.

  • Brewing unit seal set: Replacement O-rings/gaskets (red/black elastomer seals of various diameters) including seals for the brewing piston and drainage valve. Specific material grades (e.g., EPDM vs. VMQ) and exact dimensional specifications are not stated.

  • Cleaning agents: Warm/hot tap water, standard dish soap (Pril brand demonstrated), and food-grade silicone grease for lubricating seals and moving drive mechanisms during reassembly.

For the brew-unit overhaul portion of this repair, the complete Jura E6 / E8 Generation 1 brewing unit is an optional replacement for the older Jura E6 platform shown here if the body or mechanism is damaged.

Products for this guide

Oval-head service bit for Jura coffee machines — 15203

For the Jura oval-head casing fasteners specified in this guide. This is the access tool; replacement parts still need to match the exact machine.

Preparation and precautions

  • Electrical shock hazard: Always disconnect the main power plug from the wall outlet before removing any panels or servicing internal components. Confirm the power cord is completely isolated.

  • Burn hazard: Allow the heating block (thermoblock) to cool completely before handling.

  • Loose component removal: Remove the water tank, drip tray, coffee grounds container, bean hopper lid, and ground coffee chute lid before handling or tilting the machine.


Step-by-step procedure

1. Housing disassembly

  1. Top cover fasteners:

    • Open the ground coffee chute lid and bean hopper area.

    • Remove the four Torx screws located on the top panel (two near the ground chute and bean container, and two forward toward the control console).

  2. Lower and rear panel fasteners:

    • Remove the single Torx screw located at the lower front on the right side panel near the drip tray guide.

    • Turn the machine around to access the lower rear panel.

    • Using the specialized Jura oval-head service tool, remove the two oval-head screws located at the bottom left and bottom right of the rear casing.

  3. Panel removal:

    • Slide the side panels slightly toward the rear, then release them by lifting upward and outward from their retaining tracks.

    • Remove the left and right side panels to expose the internal chassis.

    • Remove the single screw securing the front upper top cover above the control interface, then remove the upper top housing section.

    • Remove the rear cover panel to expose the main power and logic printed circuit boards (PCBs).

2. Temperature sensor removal and diagnosis

  1. Locating the sensor:

    • On the component side of the machine, locate the black plastic shroud enclosing the aluminum thermoblock heating element.

    • Using a 4 mm hex bit, unscrew the central bolt securing the black plastic thermoblock shroud and remove the shroud.

    • Carefully slide the thermoblock forward out of its mounting pocket.

    • On the thermoblock, locate the NTC sensor eyelet secured with a Torx screw against the aluminum casing next to the heating element terminals.

  2. Tracing the wiring harness:

    • Follow the thin sensor cable leading from the thermoblock across the upper plastic internal framework and down along the cable guide toward the rear control board.

    • Note the routing path through the plastic retaining clips along the side and top of the chassis.

  3. Disconnecting the sensor:

    • At the rear PCB assembly, locate the upper multi-pin connector bank.

    • Identify the small white 2-pin connector at the top of the logic board that carries the two black wires of the temperature sensor.

    • Carefully pull the connector straight out from the board header.

    • Unclip the wire harness from the chassis and completely remove the faulty sensor assembly.

  4. Bench testing:

    • Set a digital multimeter to resistance (\Omega).

    • Place the probe tips across the pins inside the sensor connector plug:

      • The faulty sensor displayed 0.L (infinite resistance / open circuit).

      • The replacement sensor displayed approximately 132\text{ k}\Omega\text{ to }137\text{ k}\Omega at ambient workshop temperature.

3. Temperature sensor installation

  1. Connect the 2-pin plug of the new sensor assembly into its designated socket on the upper edge of the rear control board.

  2. Route the sensor wires through the dedicated chassis guide clips along the side frame, across the top frame, and down to the front of the thermoblock housing.

  3. Position the sensor eyelet between the two alignment tabs cast into the thermoblock housing.

  4. Fasten the securing screw snugly by hand using a screwdriver to hold the sensor eyelet firmly against the thermoblock surface. Do not over-tighten, as the aluminum housing threads can strip.

  5. Re-seat the thermoblock into its internal mounting cradle, ensuring all electrical connections and fluid lines remain unpinched.

  6. Refit the protective black plastic thermoblock cover and secure it with the central 4 mm hex bolt.


4. Brewing unit disassembly, cleaning, and overhaul

Note: In this service case, the brewing unit exhibited severe accumulation of rancid coffee grounds, calcification, and mold throughout the guide rails and chamber.

  1. Brewing unit removal:

    • Release the fluid feed pipe connected to the brewing unit.

    • Remove the mounting screws securing the brewing unit framework inside the machine chassis (including the lower mounting screw, which may require penetrating clearing if corroded).

    • Carefully slide the brewing unit assembly out of the machine housing.

  2. Disassembly of the brewing unit:

    • Remove the external drainage channel and lower fluid guides.

    • Vacuum and brush off heavy exterior coffee deposits.

    • Release the retaining clips and unthread the structural screws holding the two outer plastic side frames together.

    • Detach the upper drive gear, connecting rods, and helical worm drive shaft.

    • Unseat the brewing cylinder and piston assembly.

    • Remove the drainage valve assembly from the bottom of the brewing unit framework.

  3. Drainage valve overhaul:

    • Open the drainage valve housing.

    • Inspect the internal valve stem, inlet nozzles, and seals.

    • Remove old, flattened, or crusty rubber O-rings and replace them with new seals from the gasket set.

  4. Deep cleaning and component preparation:

    • Thoroughly scrub all plastic housings, pistons, perforated screen plates, drive gears, and slides using warm water, a soft brush, and dish soap until all coffee oils, dried grounds, and residues are removed.

    • Rinse thoroughly with clean water and dry all parts.

  5. Reassembly of the brewing unit:

    • Fit new piston ring seals onto the upper and lower brewing pistons.

    • Apply a light film of food-grade silicone grease to the piston seals, the inside walls of the brewing cylinder, and the guide tracks.

    • Reinsert the drainage valve and snap its housing into the main framework.

    • Reinstall the lower piston, upper piston mechanism, and helical drive spindle.

    • Align the side support brackets and snap all retaining clips into place.

    • Reinstall and tighten the structural Torx frame screws.

    • Manually cycle the drive mechanism by rotating the large white gear to verify smooth mechanical movement without binding.


5. Reassembly and testing

  1. Component installation:

    • Clean the empty brewing compartment inside the machine chassis.

    • Reinstall the overhauled brewing unit into the chassis and fasten its mounting screws.

    • Reconnect the fluid lines and secure all hose retaining clips.

    • Reinstall the cleaned coffee grounds chute and bean feed guide.

  2. Provisional assembly for live testing:

    • Mount the front and side covers provisionally so that safety interlocks and fluid spouts align, or set up a collection vessel beneath the dual coffee spout and hot water nozzle.

    • Connect the machine to the electrical mains.

  3. Power-on and system initialization:

    • Turn the power switch on.

    • The display turns on and proceeds past the initial boot sequence without triggering "Error 2".

    • When prompted with "Filterbetrieb / Filter einsetzen / Kein Filter" (Filter operation / Insert filter / No filter), select "Kein Filter" (or as appropriate).

    • The screen shows "Gerät heizt auf" (Appliance heating up) accompanied by a thermometer icon, indicating the thermoblock circuit is actively heating.

  4. System rinsing:

    • Once heated, the display prompts for a system rinse.

    • When prompted with "Drehknopf öffnen" (Open dial), open the steam/hot water valve dial on the front right.

    • Hot water and steam discharge into the container as the pump primes the hydraulic system.

    • When prompted, close the rotary dial.

    • The machine performs an automatic coffee circuit rinse through the central coffee dispensing spouts.

    • The display changes to the standard ready menu showing drink options (Espresso, Coffee, Cappuccino, Milk Foam).

  5. Brewing verification:

    • Ensure the bean container has fresh coffee beans.

    • Initiate a standard "Kaffee" (Coffee) cycle.

    • Verify that the grinder runs, the brewing unit compresses the puck smoothly, coffee discharges evenly from both dispensing spouts with good crema, and the spent coffee puck is ejected cleanly into the waste area.


Result and troubleshooting if the issue persists

Demonstrated outcome

Replacing the open-circuit NTC temperature sensor completely eliminated the "Error 2" code, allowing the machine to heat normally. The comprehensive cleaning, re-sealing, and lubrication of the brewing unit restored smooth mechanical cycling, fluid priming, and coffee dispensing across standard operational cycles. Diagnostic readouts retrieved via Bluetooth showed this particular machine had dispensed over 22,295 total products prior to repair.

If Error 2 persists after sensor replacement

  1. Connector seating: Verify that the 2-pin white sensor plug on the upper rear logic board is fully seated in the correct header.

  2. Wire harness continuity: Check the wire harness between the PCB and thermoblock for pinches, cuts, or abrasions caused by chassis clips.

  3. Sensor thermal contact: Ensure the sensor eyelet is screwed tightly against the bare metal surface of the thermoblock without foreign material or corrosion impeding thermal transfer.

  4. Logic board circuit: If a new sensor of correct resistance (~130\text{ k}\Omega\text{ to }140\text{ k}\Omega at room temperature) does not clear the error upon power cycle, the analog-to-digital input circuit on the main logic board may be damaged.

Limitations and missing specifications

  • Part numbers: Specific OEM part numbers for the Jura E6 temperature sensor and brewing unit O-ring repair kit were not specified.

  • Sensor characteristics: The exact nominal resistance at 20^\circ\text{C} or 25^\circ\text{C} and beta curve (\beta-value) for the NTC sensor were not stated; only a room-temperature multimeter reading of \approx 132\text{--}137\text{ k}\Omega was demonstrated.

  • Torque values: Fastener torque specifications for housing screws, the thermoblock 4 mm hex mounting bolt, and the sensor retaining screw are not specified; tighten hand-tight to avoid stripping plastic or aluminum threads.

  • Chemical specifications: The detergent used for soaking brewing unit parts was commercial dish soap; specific exposure times, food-contact certifications, and descaling chemical specifications were not established.

Related guides