Jura S-Series: Coffee Grinder Removal Procedure
Jura S-Series: Coffee Grinder Removal Procedure
Overview and applicability
This technical guide details the procedure for removing the complete coffee grinder assembly from a Jura S-series (Jura S-Serie) automatic espresso machine.
The procedure applies to the internal mechanical and electrical detachment of the grinder once the machine's external housing and top cover have already been removed. It covers disconnecting the mechanical grind-adjustment linkage, removing the mounting fasteners, detaching the motor wiring connectors, and disengaging the thermal fuse sensor. Disassembly of the external housing and internal servicing of the grinder burrs or motor components are outside the scope of this procedure.
Tools, materials, and replacement parts
The following tools are required:
Torx T10 screwdriver
Needle-nose pliers
The video demonstrates removal of the existing assembly; no specific replacement part numbers, torque values, or motor electrical ratings are specified.
Preparation and precautions
Before beginning any work on the interior of the machine:
Disconnect the machine completely from the electrical mains power supply by pulling the power plug.
Empty and remove the water tank.
Empty the coffee bean hopper completely (for example, using a vacuum cleaner to remove remaining beans and grounds).
Ensure the machine's outer housing and top panel are already dismantled so the internal chassis and top of the grinder are fully accessible.
Step-by-step procedure
1. Detaching the grind adjustment shaft
Locate the grind adjustment shaft (Achse der Mahlgradverstellung) positioned at the top edge of the grinder mounting area.
Carefully pull the adjustment shaft upward and off its engagement point to disengage the adjustment mechanism from the grinder collar.
2. Removing the grinder mounting fasteners
Identify the three Torx screws securing the grinder assembly to the internal chassis ring.
Using a Torx T10 screwdriver, unscrew and remove all three fasteners. Keep the screws safe for reinstallation.
3. Lifting the grinder assembly
Grasp the grinder housing firmly.
Lift the grinder assembly straight upward out of the chassis opening just far enough to access the wiring and attached components underneath.
4. Disconnecting the motor electrical leads
Support the lifted grinder assembly with one hand to prevent strain on the wiring harness.
Locate the push-on spade connectors attached to the bottom terminals of the grinder drive motor.
Using needle-nose pliers, grip each electrical connector by its terminal sleeve and pull it straight off the motor pin. Do not pull directly on the wires.
5. Releasing the thermal cut-off sensor
Locate the thermal protection fuse (Übertemperatursicherung) mounted into the side/bottom bracket of the grinder housing.
Use needle-nose pliers to gently depress and release the plastic retention tab (Rastnase).
Slide the thermal fuse and its clip free from the grinder body.
Carefully lift the grinder entirely clear of the machine chassis and place it on a clean work surface.
Reassembly and testing
Reinstallation follows the reverse order of removal:
Slide the thermal cut-off sensor into its mounting slot on the grinder body until the retention tab clicks securely into place.
Connect the electrical spade leads to the motor terminals using needle-nose pliers, ensuring tight and fully seated connections.
Lower the grinder assembly into its housing recess in the chassis, ensuring that wiring is not pinched beneath the motor.
Align the mounting holes and secure the assembly with the three Torx T10 screws.
Reinstall the grind adjustment shaft onto the grinder collar mechanism.
Reinstall the machine housing panels and water tank before connecting the unit to mains power.
Conduct a test grinding cycle to confirm motor operation and verify that the grind adjustment lever moves smoothly through its adjustment range.
Limitations and missing specifications
Housing Disassembly: The initial removal of the outer casing, bean hopper lid, and top cover panels is not included in this procedure; the machine must already be opened.
Component Specifications: Exact electrical ratings for the grinder drive motor, part numbers for the grinder assembly, and specific torque specifications for the T10 chassis screws are not documented in the source.
Burr Servicing: This procedure covers removal of the complete grinder unit only; it does not detail calibrating or replacing the internal grinding burrs.