Jura S-Series (New Generation): Carrier Plate Removal and Disconnection
Jura S-Series (New Generation): Carrier Plate Removal and Disconnection
Overview and applicability
This technical article covers the removal and partial disconnection of the lower component carrier plate (Trägerplatte) on the newer-generation Jura S-series coffee machines.
The carrier plate forms a sliding sub-chassis at the base of the machine that supports several heavy and central components, including the vibration pump, the membrane regulator (pulse damper), and the main power transformer. Removing or sliding out this carrier plate is required to replace the pump, service fluid couplings, access internal wiring, or replace the carrier assembly itself.
Applicability limits: This procedure specifically applies to Jura S-series models using the newer-generation internal chassis configuration. It does not cover earlier-generation Jura S-series chassis designs or other Jura model families with differing internal layouts.
Symptoms and diagnosis
Removal of the carrier plate is typically indicated when:
The vibration pump has failed, lost pressure, or is leaking.
The membrane regulator or its associated fluid couplings require replacement or seal inspection.
The transformer, lower wiring harness, or main power switch requires servicing.
The plastic carrier plate itself is cracked or broken.
This procedure describes access and mechanical removal; specific diagnostic measurements (such as coil resistance or pump delivery pressure) must be evaluated prior to disassembly based on observed operational symptoms.
Tools, materials, and replacement parts
Required tools
Needle-nose pliers (Spitzzange)
Slotted screwdriver, size 5 (Schraubendreher Schlitz Gr. 5)
Materials and replacement parts
Replacement carrier plate, vibration pump, or membrane regulator (as needed depending on the underlying fault). Specific replacement part numbers vary by exact production revision and are not specified in the demonstrated procedure.
Preparation and precautions
Safety precautions
Electrical shock hazard: The carrier plate contains mains-voltage connections, the transformer, and pump wiring. Always disconnect the machine from the electrical outlet by pulling the mains plug before opening the machine or touching internal components.
Water damage hazard: High-voltage wiring sits directly adjacent to hydraulic lines on the carrier plate. Ensure the water system is depressurized and drained to avoid water contacting electrical terminals.
Initial preparation
Turn off the machine and unplug the power cord from the mains socket.
Remove and empty the water tank.
Empty the bean hopper as thoroughly as possible (a vacuum cleaner can be used to remove residual beans).
Remove the outer casing and rear panels of the machine. The internal rear cavity must be fully exposed before beginning the carrier plate removal.
Step-by-step procedure
1. Disconnect the membrane regulator hydraulic fitting
Locate the membrane regulator mounted directly onto the output/intake side of the vibration pump on the left side of the lower carrier plate.
Using needle-nose pliers, grasp and withdraw the retaining metal clip (Klammer) securing the fluid connection to the membrane regulator.
Using the needle-nose pliers, gently pull the elbow connector / fluid connection piece (Verbindungsteil) straight out of the membrane regulator housing. Set the clip and connector aside, ensuring the sealing O-ring is not lost or damaged.
2. Disconnect the silicone hose
Locate the flexible silicone fluid hose connected to the lower assembly on the carrier plate.
Using needle-nose pliers, grip the hose near the hose barb and carefully ease it backward until it slides completely off the connection nozzle. Avoid tearing the silicone.
3. Release the carrier plate latching tabs
Locate the two plastic retaining snap-fit tabs (Rastnasen) securing the bottom front edge of the carrier plate to the main machine chassis base.
Using your fingers or a size 5 slotted screwdriver, press the two retaining tabs upward/inward to release them from their catches in the chassis frame.
4. Withdraw the carrier plate
Carefully slide the entire carrier plate straight back toward the rear of the machine until it clears the chassis retention rails.
Tilt the carrier tray slightly outward to reveal the wiring leading to the vibration pump.
5. Disconnect the pump electrical connection
Identify the spade connector plug wired to the terminal of the vibration pump.
Firmly pull the electrical connector off the pump terminal by hand.
Tilt and guide the carrier plate free from the chassis cavity. The plate, holding the pump, transformer, and associated wiring blocks, can now be swung clear or rested flat behind the machine for component service or replacement.
Reassembly and testing
Reassembly sequence
Position the carrier plate at the rear chassis opening and reconnect the electrical spade terminal firmly onto the vibration pump.
Align the carrier plate with the lower chassis guide tracks, ensuring no internal wires are pinched underneath the tray or behind the transformer.
Push the carrier plate forward into the machine until both lower retaining snap tabs click firmly into place.
Reinstall the flexible silicone hose fully onto its designated hose barb.
Insert the fluid connection piece into the membrane regulator port, ensuring the O-ring seats cleanly, and push the metal retaining clip back into its locking grooves until fully seated.
Reinstall the outer machine panels.
Testing
Reinstall the water tank and refill with water.
Plug the machine into the electrical mains.
Power on the machine and initiate a rinse cycle or hot water dispensing cycle.
Visually inspect the membrane regulator connection and the silicone hose barb for any signs of water leakage under line and operating pressure.
Result and troubleshooting if the issue persists
Completing this procedure releases the main hydraulic and electrical anchoring points of the carrier tray, allowing component replacement (pump, regulator, transformer).
If fluid leaks appear after reassembly:
Leak at membrane regulator: The retaining clip may not be fully engaged in both retention grooves, or the internal O-ring on the connecting piece may be pinched, rolled, or degraded. Remove the clip, inspect the seal, and reseat.
Leak at silicone hose: Inspect the tip of the silicone hose for splits or stretching. If stretched, trim a small section off the end or secure with an appropriate fluid line clamp.
Limitations and missing specifications
Exact machine sub-models: The procedure covers the general "new generation" chassis layout of the Jura S-series. Sub-model variations (such as S7, S9, S90, S95, Avantgarde, or One Touch) may feature slight differences in auxiliary wiring harness routing.
Fasteners and panel removal: The removal of the outer housing panels and screws is a prerequisite not detailed in this specific sub-assembly procedure.
Torque and replacement seal sizes: Exact O-ring dimensions and material grades for the membrane regulator connection piece are not provided in the source material and must be checked against model-specific parts diagrams.
Related guides
Replacing and Calibrating the Grinder Burrs on Jura S-Series Coffee Machines — Related service for the S series platform; use the model and component scope stated in that guide.
Overhauling the Jura S-Series Outlet Valve (Auslaufventil) — Related service for the S series platform; use the model and component scope stated in that guide.
Jura S-Series Drainage Valve Overhaul and Seal Replacement — Related service for the S series platform; use the model and component scope stated in that guide.