Jura X-Series Coffee Grinder: Burr Set Replacement and Alignment
Jura X-Series Coffee Grinder: Burr Set Replacement and Alignment
Overview and applicability
This technical article details the disassembly, replacement, and alignment of the conical burr set (grinding ring and grinding cone) on the grinder assembly used in Jura X-series automatic coffee machines.
The procedure applies to the standalone grinder assembly after it has been removed from the coffee machine chassis. Removal of the machine casing and extraction of the grinder assembly from the housing are not covered in this guide.
Symptoms and diagnosis
Replacement of the grinding burrs is typically indicated when:
The grinder runs, but ground coffee output is insufficient, excessively coarse, or uneven despite fine grind settings.
The coffee machine displays bean filling or flow errors due to slow grinding throughput.
The cutting edges of the grinding cone (Mahlkegel) and grinding ring (Mahlring) are rounded, chipped, or worn from normal service life or foreign objects.
Visual inspection of the burr cutting surfaces after disassembly confirms mechanical wear or damage.
Tools, materials, and replacement parts
Tools required
Torx T20 screwdriver
Slotted (flat-blade) screwdriver, size 5 (Gr. 5)
Permanent marker or paint pen (if existing alignment marks are faded or absent)
Replacement parts and hardware
Replacement burr set for Jura X-series grinder (matched outer grinding ring and inner grinding cone)
Internal hardware present in the assembly (to be inspected and reused):
3 steel balls (detent/drive balls)
3 coil springs
1 central securing screw
1 intake auger (Einzugsschnecke)
Impeller / conveyor disc (Förderteller)
Burr carrier components and felt/sealing ring
Note: Specific part numbers, chemical cleaning agents, and tightening torque specifications are not provided in the source documentation.
Products for this guide
Torx T20/T20H screwdriver — STHT16179-0
For the T20/T20H Torx fasteners specified in this guide.
Preparation and precautions
Before working on the appliance or handling electrical components:
Electrical safety: Disconnect the machine from the electrical mains power supply by pulling the power plug. Ensure all electrostatic discharge (ESD) and safety guidelines (such as DIN VDE standards) are followed for electrotechnical assemblies.
Machine preparation: Empty and remove the water tank. Empty the bean hopper as completely as possible (a vacuum cleaner may be used to clear residual coffee beans).
Ensure a clean, flat work surface is prepared so small internal components (such as the three steel balls and springs) are not lost when the drive disc is disassembled.
Step-by-step procedure
1. Removing the outer adjustment ring and checking alignment marks
Hold the grinder motor firmly. Release the three plastic retaining tabs securing the black toothed outer adjustment ring to the white grinder body.
Lift the black adjustment ring straight off the assembly and set it aside.
Inspect the side of the grinder housing for an alignment mark across the adjustment ring, the grinder body, and the internal threaded ring.
Verify that the alignment mark extends across all three relevant parts. If the mark is missing, incomplete, or worn away, apply a clear reference line across the parts with a marker before continuing.
2. Disassembling the grinding ring holder
Rotate the outer threaded adjustment ring counterclockwise to loosen and unthread it.
Lift the grinding ring holder straight up and out of the upper grinder housing.
Place the ring holder assembly on the workbench.
3. Removing the grinding cone and drive assembly
Insert the screwdriver into the central screw located inside the center of the grinding cone and intake auger.
Hold the conical grinding cone securely with your fingers so it cannot rotate while loosening the screw counterclockwise.
Remove the central screw and the plastic intake auger (Einzugsschnecke), keeping a firm grip on the grinding cone underneath.
Grasp the grinding cone at its center and invert the grinder motor assembly.
Slide the grinding cone together with the conveyor disc (Förderteller) straight downward out of the bottom of the upper housing.
Remove the three small coil springs from their locating pockets in the lower carrier.
Separate the plastic carrier housing to access the lower conveyor disc.
Remove the three steel ball bearings and the metal conveyor plate.
4. Replacing the outer grinding ring
Take the grinding ring holder subassembly. Using a slotted screwdriver, carefully press the two inner locking tabs inward and slightly downward to release the lower holder base.
Separate the plastic base and the felt sealing gasket ring from the upper collar.
Using the slotted screwdriver, gently lever one of the inner retaining clips outward just enough to tilt the worn grinding ring out of its housing.
Remove the old grinding ring.
Take the new grinding ring and slide one edge underneath one of the retaining tabs in the collar.
Press firmly inward and downward on the opposite side of the ring until it snaps securely into place beneath the retaining tabs.
Reassemble the ring holder base:
Ensure the felt gasket ring is correctly positioned.
Align the guide tabs on the lower part with the corresponding openings in the collar.
Push the parts together firmly until the locking tabs snap into place.
5. Assembling the new grinding cone, balls, and drive springs
Place the new grinding cone onto the conveyor disc (Förderteller). Ensure the locating holes in the cone align precisely with the holes in the disc.
Insert the three steel balls into the three respective aligned holes.
Insert one coil spring into each hole directly on top of the steel balls.
Align the assembled cone and disc with the drive shaft:
Match the three springs with the corresponding recesses in the motor coupling housing.
Push the assembly upward into the grinder body until it seats fully on the shaft.
6. Installing the intake auger and securing the cone
Place the intake auger (Einzugsschnecke) into the center of the grinding cone. Ensure the guide key on the underside of the auger engages the mating slot in the conveyor disc.
Insert the central securing screw through the intake auger.
Hold the auger firmly in place using thumb pressure to prevent it from shifting out of the drive slot while threading the screw clockwise.
Tighten the central screw with the screwdriver until fully seated and snug while preventing the cone from rotating.
Inspection check: Look directly into the side coffee grounds discharge chute. Confirm that there is zero visible gap between the bottom edge of the grinding cone and the conveyor disc. If a gap is visible, the auger guide or springs are improperly seated and must be disassembled and re-aligned.
Reassembly and testing
Insert the assembled grinding ring holder into the top of the grinder housing.
Thread the outer ring clockwise into the grinder body.
Continue rotating the ring clockwise until the factory or user-applied alignment marks on the threaded ring and grinder body form an exact straight line.
Align the black outer toothed adjustment ring with the upper collar and snap it straight down onto the three retaining tabs until fully locked.
Confirm that the assembly turns smoothly within its adjustment range without binding.
After reinstalling the grinder into the coffee machine and reconnecting electrical connections and panels, run 2–3 brewing cycles with beans to clear residual air, season the new burrs, and evaluate grind fineness and puck consistency.
Limitations and missing specifications
Machine disassembly: Specific chassis screw locations, cable disconnection steps, and grinder mounting removal inside the coffee machine housing are not documented.
Torque values: No numerical tightening torque is specified for the central securing screw; tighten snugly without stripping the plastic intake auger.
Burr specifications: Specific outer/inner burr diameters, tooth geometry variants, and factory part numbers are not specified in the source.
Related guides
Jura X-Series Brewing Unit and Drainage Valve Overhaul — Other maintenance for this machine family; follow the scope stated in that guide.