Jura S-Series: Removing the Steam Thermoblock (New Generation)
Jura S-Series: Removing the Steam Thermoblock (New Generation)
Overview and applicability
This technical procedure describes the removal and disconnection of the new-generation steam-sector thermoblock (heating block) in a Jura S-series automatic coffee machine.
Applicability is confirmed for Jura S-series models utilizing the dual-thermoblock setup with the new-generation round steam thermoblock mounted inside a sheet-metal carrier bracket. This procedure specifically documents the teardown required to extract the steam thermoblock and its supporting structure from the rear cavity of the machine.
Symptoms and diagnosis
Replacement or removal of the steam thermoblock is typically indicated when the steam or hot-water system fails to heat, leaks internally around the thermoblock fittings, or experiences severe thermal sensor / heating element circuit faults.
The procedure begins with the machine casing already open and the outer side and back panels removed, focusing strictly on disconnecting electrical pathways, fluid lines, and mounting brackets to remove the block.
Tools, materials, and replacement parts
Tools required
Torx T15 screwdriver
Long-nose pliers (needle-nose pliers)
Replacement parts and materials
Replacement Jura S-series steam thermoblock (new generation), if replacing a defective block (exact part number depends on the specific machine sub-model and is not stated).
Preparation and precautions
Electrical safety: Disconnect the machine from the electrical mains power by unplugging the power cord before opening the housing or touching internal wiring. Adhere to all applicable electrical safety regulations (such as ESD and VDE standards).
Water and bean removal: Empty and remove the water tank. Empty the coffee bean hopper (using a vacuum cleaner if necessary) to prevent spillage.
Thermal and burn hazard: If the machine was recently operating, allow the heating blocks and internal fluid pathways to cool down completely before handling.
Residual pressure: Relieve any trapped pressure in the hydraulic lines prior to disconnecting fluid tubes.
Step-by-step procedure
1. Releasing frame screws and initial sensor wiring
At the rear interior of the machine, locate the two Torx T15 retaining screws on the structural housing frame (one on the left side rail and one near the central plastic structure). Remove both screws using a Torx T15 screwdriver.
Locate the two push-on spade connectors leading to the NTC temperature sensors mounted on the thermoblocks.
Disconnect both NTC sensor spade terminals by pulling them firmly off their mating posts.
Trace the remaining single spade lead associated with the thermoblock sensors along the cable run and disconnect it.
2. Disconnecting grounding and pump connections
Unplug the yellow/green protective ground (earth) wire terminal from the metal bracket of the thermoblock assembly.
Route the yellow/green wire out of the central cable routing channel.
Unplug the additional spade connector located directly below the ground terminal on the metal assembly.
Trace and pull the yellow/green grounding wire free from the lower chassis clips so it is completely released.
Locate the black electrical plug connected to the water pump terminal at the bottom left and unplug it.
3. Disconnecting the solenoid valve and exposing the control board
Locate the blue plug connected to the solenoid valve (magnet valve) on the left side and unplug it.
Unroute the associated blue and brown wires from the wire channels and guides.
Locate the white plastic protective cover over the main logic/power electronic board on the right side.
Release the retaining clips on the white cover and pull it downward and away from the electronic board to expose the PCB connectors.
Identify the wiring plug originating from the transmission/gear motor connected to the lower section of the circuit board. Unplug this connector from the board.
Carefully unroute all disconnected wires and harness leads from the cable routing guides along the board housing, freeing the wiring loom from the central column.
4. Disconnecting high-pressure water hoses
Using long-nose pliers, extract the metal retaining hairpin clip securing the high-pressure water hose into the top fitting of the solenoid valve.
Grip the high-pressure hose and pull it straight out of the solenoid valve coupling.
Move down to the membrane regulator (located above the pump). Using long-nose pliers, pull out the metal retaining clip securing the connector piece.
Pull the connector fitting straight out of the membrane regulator housing.
Trace the loose connector and associated hoses out through the rear frame structure.
5. Releasing the lower bracket and extracting the thermoblock carrier
Locate the cream-colored plastic bracket/carrier below the thermoblock assembly that holds fluid junctions. Pull this carrier assembly straight downward and out of its frame seat to free the lower hose junctions.
Grasp the metal support bracket containing the steam thermoblock assembly and pull it slightly outward and upward to unseat it from the internal chassis.
With the assembly freed from its internal mounts, swing the metal bracket outward to access the hydraulic connection at the thermoblock.
Using long-nose pliers, remove the metal hairpin clip from the hydraulic coupling on the thermoblock.
Pull the angled hydraulic coupling and its attached hose out of the thermoblock port.
Carefully lift and maneuver the entire metal thermoblock carrier unit completely out of the machine cavity, guiding remaining wires through the frame openings.
6. Removing the thermoblock from the metal mounting bracket
Place the removed thermoblock and metal carrier assembly onto a clean work surface.
Locate the two plastic snap-fit locking tabs (retaining lugs) on the plastic base holding the metal plate.
Disengage both snap tabs outward to release the metal sheet plate from the plastic housing base.
Slide and lift the metal mounting bracket upward away from the lower plastic base.
Separate the metal bracket from the thermoblock body.
Locate the central mounting nut/bolt fastening the round thermoblock into the sheet metal bracket.
Using pliers or an appropriate wrench/driver, loosen and remove the retaining screw from the bracket.
Lift and withdraw the round steam thermoblock completely out of the metal carrier bracket.
Disconnect the remaining thermal switch wiring and electrical spade terminals from the thermoblock body as needed to fully isolate the unit.
Reassembly and testing
Reinstallation sequence: Reinstallation follows the reverse order of disassembly. Ensure that:
The thermoblock is properly seated and securely bolted into the metal carrier bracket.
The sheet metal bracket snaps firmly back into both locking tabs on the lower plastic base.
New O-ring pressure seals are fitted to all high-pressure hose connections before inserting them into the thermoblock, solenoid valve, and membrane regulator ports.
All metal hairpin clips are fully seated in their grooves to lock the pressure hoses in place.
All wiring (gear motor plug, solenoid valve, pump, NTC sensors, and ground leads) is reconnected to the correct terminals and neatly routed through the original cable retainers to prevent pinching.
The white electronic protective cover is snapped back over the circuit board.
The two housing Torx T15 screws are reinstalled and tightened.
Verification checks:
Perform an initial electrical insulation/continuity check before reconnecting to mains power.
Power on the machine and inspect all hydraulic connections for water or steam leaks during the heating and steam/hot water cycles.
Limitations and missing specifications
Exact machine model identifier: The procedure covers Jura S-series machines sharing this internal chassis architecture, but specific model numbers (e.g., S7, S9, S90, S95) or exact revisions are not individually listed.
Fastener and seal specifications: Thread size and torque specification for the central thermoblock mounting screw are not specified. Dimensions and material specifications (e.g., EPDM) for the high-pressure hose O-rings are omitted.
Electrical ratings: Operating voltage, wattage, and resistance values for the heating loops and NTC temperature sensors are not provided.
Related guides
Jura S-Series (New Generation): Carrier Plate Removal and Disconnection — Housing access for this machine family before internal component service.
Replacing and Calibrating the Grinder Burrs on Jura S-Series Coffee Machines — Related service for the S series platform; use the model and component scope stated in that guide.
Overhauling the Jura S-Series Outlet Valve (Auslaufventil) — Related service for the S series platform; use the model and component scope stated in that guide.